SCADA commissioning
Verify that what happens in the field is accurately represented at the operator interface.
- Point-to-point signal verification
- Alarm, status, and analog checks
- Command and indication validation

SCADA COMMISSIONING & INTEGRATION
SCADA, solar, and power plant control systems. From inverter integration to utility interfaces, bring your project from configuration through verification and commissioning.
Confidence starts with a verified signal.
Purposeful integration. Methodical commissioning.01 / WHAT WE DO
Commissioning and integration support across utility SCADA, solar plants, protection and controls, and PPC systems.
Verify that what happens in the field is accurately represented at the operator interface.
Bring field devices, controllers, and supervisory systems together with a consistent approach.
Work through the connections and configurations that keep useful information moving.
Support solar project acceptance with coordinated witness testing, functional verification, and clear test records.
Verify protection and control functions against approved project settings, logic, and test procedures.
Integrate and verify PPC systems across the plant, connecting inverter-level operation with plant-level supervision and control.
Hands-on support at your facility to set up solar inverters, integrate the PPC, and verify the complete plant control path.
CUSTOM RTAC PROGRAMMING & SOLAR PLANT CONTROL
Custom SEL RTAC project files and power plant control systems built around your equipment, site requirements, and operating preferences.
Coordinate solar inverters, site metering, SCADA, and utility interfaces through a unified control system. Choose manual operator control or fully automatic operation, with project-specific limits, communications monitoring, fault handling, and commissioning verification.
Adjust reactive power using point-of-interconnection voltage feedback, with configured targets, deadbands, and operating limits.
Regulate toward leading, lagging, or unity power factor targets within configured plant and inverter capabilities.
Control site reactive power to a specified target, distributing requests across qualified available inverters.
Manage output limits, curtailment, and ramp rates. Allocate power across available inverters and redistribute demand within their operating capabilities.
Provide manual setpoints, start/stop commands, and inverter participation controls while retaining configured permissions and interlocks.
Support qualified automatic startup, continuous output adjustment, and controlled inverter return when communications, permissives, and operating conditions allow.
Integrate meters, weather stations, inverter diagnostics, alarms, and utility or PJM telemetry. Configure communications-loss responses, fault handling, and recovery behavior for the site’s operating requirements.
CUSTOM HMI DESIGN & INTEGRATION
PollRate Systems develops custom human-machine interfaces (HMIs) around the way you operate. Bring plant status, trends, alarms, and controls into a clear interface for local operators or authorized remote users.
Discuss your control systemEND-TO-END SOLAR INTEGRATION
Connect the full information and control path, with verification at each interface.
Measurements, status,
and command response
Plant-level setpoints,
feedback, and control
Point mapping, telemetry,
and operator visibility
Project-specific telemetry
and control connections
Integration support for connections to National Grid, FirstEnergy, and PJM, including signal mapping, communications verification, and coordinated end-to-end testing against project-specific interface requirements.
Interface architecture and test scope are tailored to each project.02 / HOW WE WORK
Every project has its own equipment, requirements, and operating constraints. The work starts by understanding yours.
Review the scope, device interfaces, point lists, and commissioning requirements.
Align communications, point mapping, and operator displays around the project’s needs.
Work through agreed test procedures, document findings, and address discrepancies.
Capture configurations, test results, and outstanding items for a clear transition.
03 / START A CONVERSATION
Planning a solar witness test, verifying protection and controls, or connecting inverters through a PPC to utility and PJM interfaces? Let’s talk about your scope.
Email Edward Davis edavis@pollratesystems.com